Property |
Test Methods |
Typical Value |
Surface Finish |
Gloss Meter 60° Reflection |
80% to 90% |
Thickness |
Micrometer, Federal Bench Type |
130 micron |
Tensile Strength |
Tensile Tester 51 mm jaw seperation; crosshead speed of 5.1 mm/s, web direction |
≥ 1.0 kg/cm width |
Elongation |
Instron Tensile Tester as above |
≥75% • Black ≥ 40% |
Shelf Life |
Free from excessive moisture, temperature, direct sunlight |
1 year from factory shipment |
Application Temperature Range |
Immersed for 100 hours at 21°C |
5°C to 38°C 15°C to 32°C optimum |
Service Temperature Range |
Films applied to etched aluminum panels 24 hours prior to testing |
-54°C to 71°C |
Peel Adhesion |
PSTC-1, 15 min RT, 21°C |
≥ 0.78 kg/cm |
Liner Release |
TLMI, 760 cm/min |
15 g/cm |
Humidity Resistance |
1. LS-300 method 4.4.10 2. ASTM-D4956-89 |
No appreciable effect |
Fungus Resistance |
1. LS-300 method 4.412 2. ASTM-D4956-89 |
No appreciable effect |
Gasoline Resistance |
Film applied to etched aluminum panels 24 hours prior to testing LS-300 method 4.4.6 |
No appreciable effect |
Terms & Conditions
The following is made in lieu of all warranties expressed or implied:
All statements, technical information and recommendations published by Arlon relating to Arlon products are based on tests believed to be reliable and within the accuracy of the equipment used to obtain the specific values. Their accuracy or completeness is not guaranteed and Arlon makes no warranty with regard thereto. Seller’s and manufacturer’s only responsibility shall be to replace any quantity of the product proved defective. Seller and manufacturer shall not be liable for injury, loss or damage, direct or consequential, arising out of use or the inability to use the product. Nor shall seller or manufacturer be liable for any costs or expenses incurred in the processing or printing on the product. Before using, user shall determine the suitability of the product for its intended use. User assumes all risk and liability of every nature in connection therewith. No statements or recommendations other than those contained in the technical information published by Arlon shall have force or effect unless contained in an agreement manually signed by the of officers of seller and manufacturer.